Robotic vacuum cleaners generally support 2.4G WiFi and Bluetooth technology.
The following introduction is based on this assumption.
a. Required Standards:
GB 17625.1-2022
GB 4343.1-2018
GB 4706.1-2005
GB 4706.7-2014
b. Notes: Key components must be certified, including adapters, PCBs, casings, internal and external wiring, transformers, cooling fans, batteries, etc.
After certification, a factory audit is required, along with annual follow-up audits.
c. Certification Information Inquiry: The query website varies depending on the issuing authority. If issued by CQC, it can be checked at:
webdata.cqccms.com.cn/webdata/query/CCCCerti.do
a. Required Standard: MIIT [2021] No. 129
b. Notes: CCC certification requires only two complete units, but SRRC certification requires processing the test samples:
- Bluetooth/WiFi requires 1 complete unit + 5 conducted frequency-fixed samples (with RF cable connections) and tools/methods for entering the Bluetooth/WiFi test mode.
- Bluetooth devices must provide Bluetooth version, antenna gain, and RF cable loss.
- WiFi devices must provide specific supported modes, antenna gain, and RF cable loss.
c. Certification Information Inquiry: Available at:
https://ythzxfw.miit.gov.cn/resultQuery
3. For Taiwan, NCC certification is required (not required for wired products):
- NCC Certification: Testing must be conducted in a laboratory in Taiwan. Preliminary testing can be done at the JJR laboratory in China. If the test passes, samples are sent to Taiwan for official testing and certification.
- Required Standards:
EN 301489
EN 55014
EN 61000
EN 60335
EN 301893
- Sample Preparation:
3pcs complete units
Conducted and radiated samples for the corresponding wireless mode
- Notes: If there is a need for certificate conversion later, country-specific testing may be required. It is best to confirm with the laboratory in advance. If certification transfer to Indonesia is needed, the CE certification must come from an SDPPI-recognized laboratory in Indonesia; otherwise, SDPPI will not accept the report. Our company is an SDPPI-recognized laboratory and can process certification via JJR China.
1.1 CE Certification (Wired):
- Required Standards:
EN 55014
EN 61000
EN 60335
- Sample Preparation:
3pcs complete units
- Standard Requirement: 2015/863/EU
- Sample Preparation: 1pcs complete unit (If there are series models, differentiated materials can be provided)
- Standard Requirement: (EC) No.1907/2006
- Sample Preparation: 1pcs complete unit (If there are series models, differentiated materials can be provided)
- fcc sdoc:
- Standard Requirement: fcc part 15B
- Sample Preparation: 1pcs complete unit
- fcc id:
- Standard Requirement: FCC Part 15C
- Sample Preparation: Conducted and radiated samples according to the wireless mode
- FCC SDOC:
- Standard Requirement: fcc part 15b
- Sample Preparation: 1pcs complete unit
24-hour online customer service at any time to respond, so that you worry!