EMC China Lab

What is the Test Report for IEC 62133-2?

Views :
Update time : 2024-07-22

iec 62133 testing, as meticulously formulated by the International Electrotechnical Commission (IEC), not only advances the international standardization process in the field of electrical and electronic engineering but also enhances global cooperation and understanding in this domain. This standard focuses on the safety and reliability of batteries, encompassing comprehensive testing and evaluation of individual cells, battery packs, and secondary lithium batteries. Its objective is to ensure that these batteries meet internationally recognized safety standards at every stage from design and production to use. Reports under IEC 62133 are considered a "safety passport" for lithium battery products within the industry. They involve not only electrical performance tests but also rigorous assessments of safety and environmental adaptability, effectively preventing potential safety risks such as overheating, short circuits, and abnormal charging.

 

What is the Test Report for IEC 62133-2?(图1)


Additionally, this standard is continuously updated, including revisions and amendments, to accommodate the development of specific products and testing methods, making it one of the widely adopted standards in the current battery safety domain.

 

iec 62133 testing Items:

1. Short-circuit test

2. Abnormal charging test

3. Forced discharge test

4. Crush test

5. Heavy impact test

6. Mechanical shock test

7. Vibration test

8. Thermal abuse test

9. Temperature cycling test

10. Low-pressure test

11. Jet flame test

 

iec 62133 testing Report Application Process:

1. Submit application form including detailed company information

2. Sign contract and complete payment

3. Send samples and provide tracking number for logistics tracking

4. Conduct formal testing

5. Review and confirm draft of testing report

6. Receive final testing report

 

JJR Laboratory in China is an IEC 17025 accredited laboratory and one of Amazon's partner laboratories, offering iec 62133 certification testing report services. Located in China, our laboratory can help you save 30% on certification costs.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
ISO 10993-10 In Vitro Skin Sensitization Test Serv ISO 10993-10 In Vitro Skin Sensitization Test Serv
04 .11.2026
In vitro skin sensitization tests assess allergic risks for safety use. JJR LAB offers ISO 10993-10 ...
What is ISO 10993 Biocompatibility Testing? What is ISO 10993 Biocompatibility Testing?
04 .11.2026
JJR is a CNAS- and ISO/IEC 17025-accredited Laboratory providing ISO 10993 compliance testing. Repor...
How to Perform a Valid CCK-8 Cytotoxicity Assay How to Perform a Valid CCK-8 Cytotoxicity Assay
04 .10.2026
A valid CCK-8 cytotoxicity assay uses WST-8 to assess cell viability via color change, with key step...
Introduction to Cytotoxicity Assay (CCK-8 Method) Introduction to Cytotoxicity Assay (CCK-8 Method)
04 .10.2026
CCK-8 assay measures viable cells via WST-8 conversion, enabling rapid, sensitive detection for drug...
What Are the Cytotoxicity Assay Methods? What Are the Cytotoxicity Assay Methods?
04 .10.2026
Cytotoxicity assays reveal cell safety by measuring viability or damage. JJR LAB outlines methods li...
What is Ingress Protection (IP) Testing and Standa What is Ingress Protection (IP) Testing and Standa
04 .08.2026
Ingress Protection (IP) defines enclosure resistance to dust and water per IEC 60529; JJR LAB verifi...
What is UL 153 Lighting Standards and Portable Lum What is UL 153 Lighting Standards and Portable Lum
04 .08.2026
UL 153 defines safety rules for portable luminaires; Amazon requires compliant testing. JJR verifies...
What is Conducted and Radiated Emissions Testing? What is Conducted and Radiated Emissions Testing?
04 .08.2026
EMC ensures EMI control & immunity; conducted (150 kHz–30 MHz) and radiated (30 MHz–6 GHz) tests...

Leave Your Message