EMC China Lab

What is the GB 4706 Testing Report for Household Appliances?

Views :
Update time : 2025-01-07

In daily life, household appliances are closely connected to our routines. But are you aware that behind these commonly used appliances, there is a strict set of safety standards safeguarding our well-being? Today, let's take a closer look at the GB 4706 standard.

 

What is the GB 4706 Standard?

GB 4706 is a national standard in China for the safety requirements of household and similar electrical appliances. It applies to various types of household appliances and exists to ensure the safety of consumers' personal and property protection while using these appliances.

 

Process for Obtaining the GB 4706 Testing Report:

1. Business Consultation: The applicant must provide product information, images, and testing requirements.

2. Engineering Quotation: Engineers provide a verbal quotation based on the information provided by the applicant.

3. Provide Information: After accepting the verbal quotation, the applicant must submit test samples to the designated agency.

4. Payment: After receiving the samples, the agency issues a written quotation, and the applicant arranges payment accordingly.

5. Sample Testing: Products are tested according to applicable standards.

6. Issuance of Report: Once testing is complete, the laboratory issues a third-party CNAS/CMA testing report, and the process is concluded.

 

Testing Items for the GB 4706 Household Appliance Report:

1. Labels and Instructions; Protection against access to live parts.

2. Starting of electric appliances; Input power and current.

3. Heating; Leakage current and electric strength under operating temperature.

4. Moisture resistance; Leakage current and electric strength.

5. Overload protection for transformers and related circuits; Abnormal operation.

6. Mechanical strength; Structure; Internal wiring; Power connections and external flexible cables.

7. Terminals for external conductors; Grounding measures; Screws and connections.

8. Electrical clearance, creepage distances, and solid insulation; Heat resistance and flammability; Corrosion resistance.

 

Documents Required for the GB 4706 Testing Report:

1. Circuit schematic diagram.

2. Printed circuit board layout and component placement diagram.

3. English manual (must include manufacturer name or trademark, model, parameters, installation instructions, and necessary safety warnings).

4. Model variation description (for multiple models in the same series, differences and similarities should be clearly listed and stamped).

5. Labels/Nameplates.

6. Product installation structure diagram/Exploded view (indicating component numbers and names).

7. List of key components (must be stamped).

8. Copy of certificates for safety-related key components (based on the "key component list," to verify whether the number, parameters, and actual sample match).

 

The Significance of the GB 4706 Standard:

The implementation of the GB 4706 standard is crucial for ensuring the safety of household appliances and similar electrical products. It provides manufacturers with a unified standard and guidelines to ensure that products meet safety requirements during design, manufacturing, and use, thus preventing accidents and damages. Furthermore, the GB 4706 standard also serves as a basis for regulatory authorities to assess and supervise the safety of household appliances and similar electrical appliances sold in the market, providing critical protection for consumer safety.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Packaging Validation ISO 11607 Test Report Packaging Validation ISO 11607 Test Report
04 .25.2025
ISO 11607 packaging validation testing provided by China’s JJR Lab ensures medical devices meet safe...
What is the ISO 11607-1 Packaging Validation Test? What is the ISO 11607-1 Packaging Validation Test?
04 .25.2025
ISO 11607-1 ensures sterile medical packaging meets global safety standards. JJR Lab in China offers...
How to get an ISO 11737-1 Test Report? How to get an ISO 11737-1 Test Report?
04 .25.2025
Bioburden testing per EN ISO 11737-1 ensures medical device safety pre-sterilization. JJR Lab in Chi...
Orthopedic Implant Cleanliness Testing Orthopedic Implant Cleanliness Testing
04 .25.2025
Orthopedic implant cleanliness is key for biocompatibility and sterilization. China JJR Laboratory o...
What is ISO 10993-23:2021 Irritation Testing? What is ISO 10993-23:2021 Irritation Testing?
04 .25.2025
ISO 10993-23:2021 evaluates irritation risks of medical devices using in vitro/in vivo methods. JJR ...
ISO 10993-23 Irritation Testing Laboratory ISO 10993-23 Irritation Testing Laboratory
04 .25.2025
ISO 10993-23 irritation testing ensures device safety for skin, eyes, and mucosa. Professional testi...
EMI Emissions Testing EMI Emissions Testing
04 .25.2025
EMI emissions testing of electric/magnetic fields & disturbance power per CISPR standards. JJR L...
EMC Standards for Medical Devices EMC Standards for Medical Devices
04 .25.2025
EMC standards like IEC 60601-1-2 are vital for medical devices. China’s JJR Lab provides testing for...

Leave Your Message