What are the CE-EMC testing standards for mobile phone chargers?

Views :
Update time : 2024-07-08

The following conditions apply to CE-EMC testing standards for mobile phone chargers:

1. The device is powered by a charger using a Micro-B USB plug cable.

2. The charging voltage is 5V ± 5%.

3. The maximum output current is limited to 500 to 1500mA.

4. The power supply of the EPS must comply with the relevant requirements of EN 60950-1: Safety of Information Technology Equipment.

 

For CE certification of chargers, the EPS test must meet the following conditions:

1. When testing the EPS, its DC output port must be connected to a simulated load that represents its connected device.

2. During testing, avoid interference from the RF signals of the testing equipment with the test results.

3. During testing, the EPS must use a Micro-B port USB cable. Its model and length must be recorded in the report.

 

For CE certification, chargers need to undergo EMC disturbance tests:

1. Radiated disturbance test.

2. Conducted disturbance test.

3. Harmonic current test.

4. Voltage fluctuation and flicker test.

 

EMC immunity tests include:

1. Radiated immunity.

2. Electrostatic discharge immunity.

3. Electrical fast transient burst immunity.

4. Conducted immunity.

5. Voltage dips and short interruptions immunity.

6. Surge immunity.

 

China JJR Laboratory provides EMC testing services related to CE certification for mobile phone chargers, including radiated disturbance, electrostatic discharge, surge, and other tests. They can help you save 20% on testing costs.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Packaging Validation ISO 11607 Test Report Packaging Validation ISO 11607 Test Report
04 .25.2025
ISO 11607 packaging validation testing provided by China’s JJR Lab ensures medical devices meet safe...
What is the ISO 11607-1 Packaging Validation Test? What is the ISO 11607-1 Packaging Validation Test?
04 .25.2025
ISO 11607-1 ensures sterile medical packaging meets global safety standards. JJR Lab in China offers...
How to get an ISO 11737-1 Test Report? How to get an ISO 11737-1 Test Report?
04 .25.2025
Bioburden testing per EN ISO 11737-1 ensures medical device safety pre-sterilization. JJR Lab in Chi...
Orthopedic Implant Cleanliness Testing Orthopedic Implant Cleanliness Testing
04 .25.2025
Orthopedic implant cleanliness is key for biocompatibility and sterilization. China JJR Laboratory o...
What is ISO 10993-23:2021 Irritation Testing? What is ISO 10993-23:2021 Irritation Testing?
04 .25.2025
ISO 10993-23:2021 evaluates irritation risks of medical devices using in vitro/in vivo methods. JJR ...
ISO 10993-23 Irritation Testing Laboratory ISO 10993-23 Irritation Testing Laboratory
04 .25.2025
ISO 10993-23 irritation testing ensures device safety for skin, eyes, and mucosa. Professional testi...
EMI Emissions Testing EMI Emissions Testing
04 .25.2025
EMI emissions testing of electric/magnetic fields & disturbance power per CISPR standards. JJR L...
EMC Standards for Medical Devices EMC Standards for Medical Devices
04 .25.2025
EMC standards like IEC 60601-1-2 are vital for medical devices. China’s JJR Lab provides testing for...

Leave Your Message