The fire and smoke mask is an air-purifying respiratory protective equipment (RPED) designed for smoke protection. It includes an air-purifying respirator that can remove harmful pollutants from the inhaled air, thereby protecting personnel from fire-related injuries. Such products use (or combine) filters, filter cartridges, gas masks, adsorbents, or catalysts to remove these pollutants.
According to Amazon's requirements, all fire and smoke masks must be tested and comply with one of the following specific regulations or standards:
1. Occupational Safety and Health Administration (OSHA) Standard: 29 CFR 1910.134 (Respiratory Protection).
2. ASTM Standard: ASTM E2952-23 (Standard Specification for Air-Purifying Respiratory Protective Equipment for Smoke Protection).
1. ASTM E2952-23 covers the design, performance, testing, and certification minimum requirements for air-purifying respiratory protective smoke escape devices, intended for immediate emergency evacuation without adult civilians entering/re-entering.
2. The purpose of ASTM E2952-23 is to provide the minimum requirements for respiratory protective escape devices, offering 15 minutes of limited protection for adult civilians fleeing fire by-products (including particulates, carbon monoxide, and other toxic gases), as well as protection against the effects of radiant heat.
3. The requirements of ASTM E2952-23 specify an air-purifying respiratory protective escape device, laboratory-tested with a service life of 15 minutes, designed to protect the head, eyes, and respiratory system from particulates, irritants, and toxic gases and vapors typically produced by fire.
4. Controlled laboratory tests to determine compliance with this specification’s performance requirements should not be considered as establishing the performance level for all situations that individuals may encounter.
5. This specification does not apply to the provision, installation, or use of air-purifying respiratory protective smoke escape devices.
6. This standard does not apply to respiratory protective escape devices used in the presence of, or potentially in the presence of, oxygen-deficient atmospheres (oxygen content below 19.58201 volume percent).
7. This standard is not intended to serve as a detailed manufacturing or procurement specification but may be referenced as the minimum requirement in procurement specifications.
8. The "unit" values expressed in SI units are considered the standard values. This standard does not include other measurement units.
9. This standard is not intended to address all safety concerns (if any) related to its use. Users of this standard are responsible for establishing appropriate safety and health practices and determining the applicability of regulatory limitations prior to use.
1. Fill out the application form;
2. Provide test samples;
3. The JJR laboratory in China arranges the test;
4. Upon test completion, draft results are provided;
5. Once confirmed, the official certificate is issued.
Test Cycle: With complete information provided, the test is completed within 5-7 working days.
24-hour online customer service at any time to respond, so that you worry!