EMC China Lab

UL 174 Test Report for Household Storage Electric Water Heaters

Views :
Update time : 2024-09-20

Electric water heaters can be categorized into three types based on their heating power: storage type (also known as volumetric or heat storage type), instant type, and fast-heating type (also known as semi-storage type). Although the regular fast-heating electric water heater and the dual-mode electric water heater are similar in size, their internal structures are quite different. Compared to storage electric water heaters, fast-heating electric water heaters are smaller in size but have higher power, making their heating speed faster than that of storage water heaters. However, fast-heating water heaters cannot achieve instant heating in spring and autumn; they still require preheating, meaning there is a waiting time. On the other hand, dual-mode electric water heaters can use the instant heating mode in spring, summer, and autumn, providing heat as soon as it is turned on.

 

UL 174 Test Report for Electric Water Heaters - Test Items:

- Temperature control and limitation tests

- Safety performance tests

- Insulation tests

- Fire and heat resistance tests

- Leakage tests

- Capacity and pressure tests

- Long-term operation tests

- Cleaning and maintenance tests

 

UL 174 Test Report Process for Electric Water Heaters:

1. Signing a contract (negotiating details and confirming product functions)

2. Filling out the application form (determining the testing standards based on product functions), sending samples with complete accessories, and providing full technical documentation

3. Conducting tests based on the application form and product functions

4. Drafting a report (client confirms the information)

5. Issuing the official report


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Packaging Validation ISO 11607 Test Report Packaging Validation ISO 11607 Test Report
04 .25.2025
ISO 11607 packaging validation testing provided by China’s JJR Lab ensures medical devices meet safe...
What is the ISO 11607-1 Packaging Validation Test? What is the ISO 11607-1 Packaging Validation Test?
04 .25.2025
ISO 11607-1 ensures sterile medical packaging meets global safety standards. JJR Lab in China offers...
How to get an ISO 11737-1 Test Report? How to get an ISO 11737-1 Test Report?
04 .25.2025
Bioburden testing per EN ISO 11737-1 ensures medical device safety pre-sterilization. JJR Lab in Chi...
Orthopedic Implant Cleanliness Testing Orthopedic Implant Cleanliness Testing
04 .25.2025
Orthopedic implant cleanliness is key for biocompatibility and sterilization. China JJR Laboratory o...
What is ISO 10993-23:2021 Irritation Testing? What is ISO 10993-23:2021 Irritation Testing?
04 .25.2025
ISO 10993-23:2021 evaluates irritation risks of medical devices using in vitro/in vivo methods. JJR ...
ISO 10993-23 Irritation Testing Laboratory ISO 10993-23 Irritation Testing Laboratory
04 .25.2025
ISO 10993-23 irritation testing ensures device safety for skin, eyes, and mucosa. Professional testi...
EMI Emissions Testing EMI Emissions Testing
04 .25.2025
EMI emissions testing of electric/magnetic fields & disturbance power per CISPR standards. JJR L...
EMC Standards for Medical Devices EMC Standards for Medical Devices
04 .25.2025
EMC standards like IEC 60601-1-2 are vital for medical devices. China’s JJR Lab provides testing for...

Leave Your Message