EMC China Lab

Rail Transit EN 50155 Electromagnetic Compatibility (EMC) Test

Views :
Update time : 2026-11-06

en 50155 testing is a critical step in ensuring the quality of electronic equipment used in rail transit. Today, let us take an in-depth look at the rail transit EN 50155 testing items.


Do All Test Items Need to Be Performed for EN 50155 Rail Transit Product Certification?

The mandatory railway test items specified in the standard must be performed, while other items can be negotiated and tested based on actual requirements.


How Long Does the EN 50155 Certification Cycle Take for Rail Transit Products?

Because the EN 50155 standard requires a large number of test items and extensive technical documentation to be submitted for review, the certification cycle is relatively long. Advance planning is recommended if certification is needed; under normal circumstances, it takes approximately 15 to 30 days.


What Are the Specific Rail Transit Electromagnetic Compatibility (EMC) Test Items?

Electrostatic Discharge (ESD) Immunity Test

1.Electronic equipment used on rolling stock: GB/T 25119-2010, IEC 60571:2006

2.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: GB/T 24338.4-2018, IEC 62236-3-2:2008

3.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008

4.Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008

5.Electronic equipment used on rolling stock: BS EN 50155:2017

6.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: BS EN 50121-3-2:2015


Radiated, Radio-Frequency, Electromagnetic Field Immunity Test

1.Electronic equipment used on rolling stock: GB/T 25119-2010, IEC 60571:2006

2.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: GB/T 24338.4-2018, IEC 62236-3-2:2008 (Clause 7)

3.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008 (Clause 6)

4.Part 5: Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008

5.Electronic equipment used on rolling stock: BS EN 50155:2017

6.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: BS EN 50121-3-2:2015


Electrical Fast Transient/Burst (EFT/B) Immunity Test

1.Electronic equipment used on rolling stock: GB/T 25119-2010, IEC 60571:2006

2.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: GB/T 24338.4-2018, IEC 62236-3-2:2008 (Clause 7)

3.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008 (Clause 6)

4.Electromagnetic compatibility – Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008 (Clause 5)

5.Electronic equipment used on rolling stock: BS EN 50155:2017

6.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: BS EN 50121-3-2:2015


Surge (Impact) Immunity Test

1.Electronic equipment used on rolling stock: GB/T 25119-2010, IEC 60571:2006

2.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: GB/T 24338.4-2018, IEC 62236-3-2:2008 (Clause 7)

3.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008 (Clause 6)

4.Electromagnetic compatibility – Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008 (Clause 5)

5.Electronic equipment used on rolling stock: BS EN 50155:2017

6.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: BS EN 50121-3-2:2015


Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields Test

1.Electronic equipment used on rolling stock: GB/T 25119-2010, IEC 60571:2006

2.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: GB/T 24338.4-2018, IEC 62236-3-2:2008 (Clause 7)

3.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008 (Clause 6)

4.Electromagnetic compatibility – Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008 (Clause 5)

5.Electronic equipment used on rolling stock: BS EN 50155:2017

6.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: BS EN 50121-3-2:2015


Power Frequency Magnetic Field Immunity Test

1.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008

2.Electromagnetic compatibility – Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008 (Clause 5)


Voltage Dips, Short Interruptions and Voltage Variations Immunity Test

1.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: BS EN 50121-3-2:2015


Conducted Disturbance at Ports / Terminal Disturbance Voltage

1.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: GB/T 24338.4-2018, IEC 62236-3-2:2008 (Clause 6)

2.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008 (Clause 5)

3.Electromagnetic compatibility – Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008 (Clause 4)

4.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: BS EN 50121-3-2:2015


Damped Oscillatory Voltage Test

1.Part 5: Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008


radiated emission test

1.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: GB/T 24338.4-2018, IEC 62236-3-2:2008 (Clause 6)

2.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008 (Clause 5)

3.Part 5: Emission and immunity of fixed power supply installations and apparatus: GB/T 24338.6-2018, IEC 62236-5:2008

4.Electromagnetic compatibility – Part 3-2: Rolling stock – Apparatus: BS EN 50121-3-2:2015


Conducted Interference Test

1.Electronic equipment used on rolling stock: GB/T 25119-2010, IEC 60571:2006

2.Electronic equipment used on rolling stock: BS EN 50155:2017


Radiated Interference Test

1.Electronic equipment used on rolling stock: GB/T 25119-2010, IEC 60571:2006

2.Electronic equipment used on rolling stock: BS EN 50155:2017


Pulse Magnetic Field Immunity Test

1.Electromagnetic compatibility – Part 4: Emission and immunity of the signalling and telecommunications apparatus: GB/T 24338.5-2018, IEC 62236-4:2008 (Clause 6)


Lightning Strike Test

1.Lightning strike test method for railway signalling and communication equipment: TB/T 3498-2018



Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Gaming Machines Export to South Korea: KC Certific Gaming Machines Export to South Korea: KC Certific
11 .27.2026
Export gaming machines to South Korea with JJR Lab. CMA, CNAS, A2LA & ISO/IEC 17025 accredited f...
What is EN IEC 60335-2-81 Certification Testing? What is EN IEC 60335-2-81 Certification Testing?
11 .26.2026
Get EN IEC 60335-2-81 testing for foot warmers & heating mats at JJR LAB. Our ISO/IEC 17025, CNA...
EN 60529 Enclosure Protection Rating Testing EN 60529 Enclosure Protection Rating Testing
11 .26.2026
EN 60529 enclosure IP protection rating testing at JJR Lab. CNAS, CMA, A2LA & ISO/IEC 17025 accr...
EN 301 489-1 V2.2.3 Radio Equipment Compliance Sta EN 301 489-1 V2.2.3 Radio Equipment Compliance Sta
11 .26.2026
EN 301 489-1 V2.2.3 radio equipment EMC testing by JJR Lab. ISO/IEC 17025, CNAS, CMA & A2LA accr...
Amazon Squishy Toy VOC Compliance and DV Verificat Amazon Squishy Toy VOC Compliance and DV Verificat
11 .26.2026
Amazon squishy toy VOC compliance & DPV verification by JJR Lab. Accredited by CMA, CNAS, A2LA &...
How to get a 16 CFR Part 1501 Test Report? How to get a 16 CFR Part 1501 Test Report?
11 .25.2026
Get your 16 CFR Part 1501 test report at China JJR Laboratory. ISO/IEC 17025, A2LA, CMA & CNAS a...
What Is ASTM F2670-2022 Certification Compliance? What Is ASTM F2670-2022 Certification Compliance?
11 .25.2026
Get ASTM F2670-2022 compliance for infant bath tubs at JJR Lab. Our CMA, CNAS, A2LA & ISO/IEC 17...
Amazon Canada Home Playground Equipment Compliance Amazon Canada Home Playground Equipment Compliance
11 .25.2026
Ensure Amazon Canada home playground equipment compliance with JJR Lab. ISO/IEC 17025, CMA, CNAS &am...

Leave Your Message