1. Accelerated Aging (1 year)

- Testing Standard: YY/T 0681.1-2018, ASTM F 1980-16

- Duration: 4 weeks

 

Physical Packaging Performance Testing Standards(图1)


2. Vacuum Leak

- Testing Standard: ASTM D3078-02, GB15171

- Duration: 2 weeks

 

3. Dye Penetration

- Testing Standard: YY/T 0681.4-2010, ASTM F1929-2015

- Duration: 2 weeks

 

4. Seal Peel/Peel Strength

- Testing Standard: YY/T 0681.2-2010, ASTM F88-15

- Duration: 2 weeks

 

5. Microbial Barrier (Wet Method)

- Testing Standard: YY/T 0681.14

- Duration: 2 weeks

 

6. Sterility

- Testing Standard:

 - Chinese Pharmacopoeia 2020 Edition, Part IV, General Chapter (1101) Sterility Test

 - United States Pharmacopeia - National Formulary General Chapter <71> Sterility Test (Effective 2013)

- Duration: 3 weeks

 

7. Appearance (Visual Inspection)

- Testing Standard: YY/T 0681.11-2014, ASTM F1886/F1886M-16

- Duration: 2 weeks

 

8. Burst Test

- Testing Standard: YY/T 0681.3-2016, ASTM F1140/F1140M-13(2020)e1

- Duration: 2 weeks

 

9. Bubble Test

- Testing Standard: YY/T 0681.5-2010, ASTM F 2096-11

- Duration: 2 weeks

 

### Packaging Validation

 

10. Packaging Validation (1 Year, 1 Node, 1 Batch)

- Includes: Accelerated Aging, Vacuum Leak, Dye Penetration, Seal Peel, Microbial Barrier (Wet Method), Sterility, Visual Inspection, Burst, Bubble

- Duration: 8 weeks

 

11. Packaging Validation (1 Year, 2 Nodes, 1 Batch)

- Includes: Accelerated Aging, Vacuum Leak, Dye Penetration, Seal Peel, Microbial Barrier (Wet Method), Sterility, Visual Inspection, Burst, Bubble

- Duration: 8 weeks

 

12. Packaging Validation (1 Year, 2 Nodes, 3 Batches)

- Includes: Accelerated Aging, Vacuum Leak, Dye Penetration, Seal Peel, Microbial Barrier (Wet Method), Sterility, Visual Inspection, Burst, Bubble

- Duration: 8 weeks

 

13. Packaging Validation (2 Years, 1 Node, 1 Batch)

- Includes: Accelerated Aging, Vacuum Leak, Dye Penetration, Seal Peel, Microbial Barrier (Wet Method), Sterility, Visual Inspection, Burst, Bubble

- Duration: 12.5 weeks


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Toothbrush FDA Certification Testing Toothbrush FDA Certification Testing
04 .17.2025
FDA certification for toothbrushes ensures safety and compliance. JJR Laboratory in China offers tes...
Snoring Device FDA 510k Standard Testing Snoring Device FDA 510k Standard Testing
04 .17.2025
JJR Lab in China offers FDA 510(k) testing for snoring devices, including ISO 10993 biocompatibility...
Single Use Intravenous Catheter Certification Test Single Use Intravenous Catheter Certification Test
04 .17.2025
China JJR Laboratory offers testing for Single-Use Intravenous Catheters, including biocompatibility...
Silicone Material Product Compliance Certification Silicone Material Product Compliance Certification
04 .17.2025
Silicone products require various certifications (RoHS, REACH, FDA, LFGB, NSF, ISO 10993, USP, UL) b...
What to Do If Cytotoxicity Test Results Are Positi What to Do If Cytotoxicity Test Results Are Positi
04 .17.2025
If cytotoxicity test results are positive, further investigation is needed. JJR Lab provides testing...
ISO 10993:5 Cytotoxicity Testing Methods ISO 10993:5 Cytotoxicity Testing Methods
04 .17.2025
Cytotoxicity testing methods include MTT, agar, membrane, and direct contact methods per ISO 10993-5...
FDA ISO 10993-1 Biocompatibility Evaluation Guidel FDA ISO 10993-1 Biocompatibility Evaluation Guidel
04 .17.2025
FDA and ISO 10993-1 guidelines outline biocompatibility evaluation for medical devices. JJR Laborato...
In Vitro Cytotoxicity Testing for Medical Devices In Vitro Cytotoxicity Testing for Medical Devices
04 .17.2025
JJR LAB provides in vitro cytotoxicity testing for medical devices, helping assess material safety, ...

Leave Your Message