Medical Device ISO 10993 Biocompatibility Test Laboratory

Views :
Update time : 2024-07-03

China JJR Laboratory is an IEC 17025 and GLP accredited laboratory, providing biocompatibility testing services for medical devices, including:

 

- Absorbent products for incontinence treatment

- Adhesives

- Blood collection and storage devices

- Bone void fillers

- Central nervous system implants

- Combination products

- Contact lenses

- Dental implants

- Devices containing antimicrobial agents

- Device raw materials

- Intraocular lenses

- Orthopedic implants

- Surgical sutures

- Vascular catheters

- Wound drainage devices

- Hemodialysis disposables

- Laparoscopes and endoscopes

- Ostomy devices

- Syringes

- Artificial blood vessels

- Implantable drug delivery devices

- Prosthetic eyes

- Reusable devices

- Urological stents

- Vascular stents

- Infusion/transfusion devices

- Orthodontic devices

- Surgical gloves

- Urological catheters

- Ventricular assist devices

- Wound dressings

 

cytotoxicity tests

- Cytotoxicity test (3 weeks)

- Cytotoxicity test (MTT method) (ISO 10993-5)

- Cytotoxicity test (Agar overlay method) (ISO 10993-5 / USP 87)

- Cytotoxicity test (Filter method) (ISO 10993-5)

- Cytotoxicity test (Direct contact method) (ISO 10993-5 / USP 87)

- Cytotoxicity test (Elution method) (USP 87)

 

Skin Irritation and Sensitization Tests

- Sensitization test (Maximization/patch method) (iso 10993-10) (6-8 weeks)

- Skin irritation test (ISO 10993-10) (3 weeks)

- Intradermal irritation test (ISO 10993-10 / USP 88) (3 weeks)

- Oral irritation test (Histopathological analysis required) (ISO 10993-10) (8-10 weeks)

- Vaginal irritation test (Histopathological analysis required) (ISO 10993-10) (8-10 weeks)

- Penile irritation test (Histopathological analysis required) (ISO 10993-10) (8-10 weeks)

- Rectal irritation test (Histopathological analysis required) (ISO 10993-10) (3 months)

- Eye irritation test (ISO 10993-10) (3-4 weeks)

 

Systemic Toxicity Tests

- Acute systemic toxicity test (ISO 10993-11 / USP 88) (3 weeks)

- Subacute systemic toxicity test (14/28 days) (ISO 10993-11) (6 weeks/8 weeks)

- Subchronic/chronic systemic toxicity test (90/180 days) (ISO 10993-11) (5 months/8 months)

- Pyrogen test (ISO 10993-11) (3 weeks)

- Local implant reaction test (Starting from 4 weeks)

- Subcutaneous implant test (ISO 10993-6)

- Muscle implant test (ISO 10993-6)

- Bone implant test (ISO 10993-6)

 

Blood Compatibility Tests

- Hemolysis test (ISO 10993-4 / GB)

- Hemolysis test (ASTM F756)

- Coagulation test (ISO 10993-4 / GB)

- Platelet count test

- Complement activation test (ISO 10993-4 / GB)

- Thrombosis test (In vivo, in vitro) (ISO 10993-4 / GB)

 

Genotoxicity / Genetic Toxicity Tests

- Genotoxicity/mutagenicity test (ISO 10993-3)

- Bacterial reverse mutation test (8 weeks)

- Mouse lymphoma test (10 weeks)

- Chromosomal aberration test (10 weeks)

- Micronucleus test (Mouse) (10 weeks)


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
ISO 10993-5 Tests for In Vitro Cytotoxicity ISO 10993-5 Tests for In Vitro Cytotoxicity
04 .03.2025
ISO 10993-5 in vitro cytotoxicity testing evaluates the toxicity of medical devices and biomaterials...
FDA Designated Cytotoxicity Testing Laboratory FDA Designated Cytotoxicity Testing Laboratory
04 .03.2025
FDA-designated cytotoxicity testing lab, JJR China, offers FDA-compliant biocompatibility testing wi...
Cytotoxicity Testing Labs Cytotoxicity Testing Labs
04 .03.2025
Cytotoxicity testing ensures medical device safety. JJR Lab provides compliant certification, meetin...
Introduction to UL94 Flammability Testing Introduction to UL94 Flammability Testing
04 .03.2025
UL94 is a key plastic flammability test for safety and compliance in electronics, automotive, and mo...
Canada Electrical Product Compliance Certification Canada Electrical Product Compliance Certification
04 .03.2025
JJR Lab tests electrical products for compliance with Canadian standards (CSA C22.2/UL), ensuring th...
Button Battery 16 CFR Part 1263 and ANSI/UL 4200A Button Battery 16 CFR Part 1263 and ANSI/UL 4200A
04 .03.2025
Button and coin batteries, and products containing them, must comply with 16 CFR Part 1263 and ANSI/...
American Certification Testing for Baby Walkers American Certification Testing for Baby Walkers
04 .02.2025
JJR Laboratory provides U.S. certification testing for baby walkers, covering design, safety, stabil...
Baby and Children's Products EU & US Certifica Baby and Children's Products EU & US Certifica
04 .02.2025
JJR Laboratory provides EU & US certification testing for baby and children‘s products, ensuring...

Leave Your Message