EMC China Lab

EMC Test Lab Germany

Views :
Update time : 2024-05-10

We understand that you are looking for an EMC (Electro Magnetic Compatibility) testing laboratory in Germany. However, we still want to help you understand us; because compared to local Germany laboratories, we can save you 30% on testing and certification costs.


EMC Test Lab Germany(图1)



EMC electromagnetic compatibility test

1. Introduction

Electromagnetic compatibility (EMC) mainly studies the interference and anti-interference issues of electronic and electrical products, that is, how to make various electronic and electrical devices, equipment or systems work normally without interfering with each other and achieve compatibility.

EMC is divided into two categories: EMI and EMS.

EMI refers to the emission characteristics of a device: the characteristics of a device emitting electromagnetic interference to the outside.

EMS refers to the immunity of equipment: the ability of equipment to resist external electromagnetic interference. The more sensitive the equipment, the worse the immunity.

2. EMC electromagnetic compatibility test product scope and test standards

1. IT Information Category:
EMC Standard: EN 55022/EN 55024  has been updated to en55032, EN55035.
Common products include: personal computers, telephones, scanners, routers, accounting machines, printers, bookkeeping machines, calculators, cash registers, copiers, data circuit terminal equipment, data preprocessing equipment, data processing equipment, data terminal equipment, dictation equipment, shredders, copiers, power adapters, chassis power supplies, digital cameras, etc.

2. AV Category
EMC Standard: EN 55013/EN 55020   has been updated to EN55032, EN55035.
Common products include: speakers, audio and video teaching equipment, video projectors, video cameras and video monitors, amplifiers, DVDs, record players and CD players CRT TVs, LCD TVs, recorders, radios, etc.

3. Household Appliances
EN 55014-1/EN 55014-2
Common products include: Electric kettle, electric kettle, meat slicer, juicer, juicer, microwave oven, solar water heater, household electric fan, disinfection cabinet, air conditioner compressor refrigerator, range hood gas water heater, etc.

4.EMC standard for lighting: EN 55015/EN 61547:
Common products include: lamp tube, ball lamp, tunnel lamp, mining lamp, street lamp, fluorescent lamp, table lamp, floor lamp, ceiling lamp, wall lamp, electronic ballast
, lampshade, ceiling spotlight, cabinet lighting, light strip, etc.

5. Medical equipment:
EMC standard: YY0505: 2012  latest standard: EN 55011: 2016/A11: 2020
common products include: radiation therapy device, electrocardiogram tester, analytical instrument, ozone therapy device, fumigation therapy device, ultraviolet light therapy device, spectrum therapy device, radio frequency comprehensive therapy device, ultrasonic nebulizer, etc.

 

6. Residential, commercial, and light industrial

EMC standards: EN 61000-6-3, en61000-6-1

Residential, commercial buildings, light industrial environments

Common products: Light industrial machinery and equipment, electrical equipment for light industrial environments, electrical equipment for commercial buildings

 

7. Heavy industry

EMC standards: EN 61000-6-4, EN61000-6-2

Heavy industrial environment

Common products: various heavy industrial machinery and equipment, electric control boxes

 

8. Measuring and testing instruments and laboratory equipment

EMC standard: EN 61326-1

Common products: various test instruments, laboratory electrical equipment, sensors, etc.

 

9. Others

 

3. EMC conventional test items

1. EMI inspection items

① Harmonic current (2nd to 40th harmonic)

②Flicker

③Conduction interference (CE)

④Radiated disturbance (RE)

2. EMS inspection items

①. Electrostatic discharge immunity (ESD);

②. Radiated electromagnetic field (80MHz~1000 MHz) immunity (RS);

③. Electrical fast transient/burst immunity;

④. Surge (lightning) immunity;

⑤. Injection current (150kHz~230MHz) immunity (CS);

⑥. Voltage sag and short interruption immunity

 

IV. EMC Electromagnetic Compatibility Test Sample Requirements

EMC electromagnetic compatibility testing requires that the product is in normal working condition. When the manufacturer arranges to send samples, the corresponding input and output loads and accessories must be sent together. The corresponding wiring instructions and installation requirements must be sent to the laboratory for confirmation in advance. If the test software needs to be installed, the software instructions must be sent to the laboratory together. Two sets of conventional supporting products are sufficient.

 

5. EMC electromagnetic compatibility test cycle

The electromagnetic compatibility test can be completed in about 2-3 weeks after receiving the test samples and fees. If there are special requirements, it can be expedited. If the test fails and rectification is required, the cycle will be postponed.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
EMC Pre Compliance Testing EMC Pre Compliance Testing
04 .24.2025
JJR Laboratory in China offers EMC pre-compliance testing, helping clients save up to 40% on certifi...
PAHs Testing (Food and Textile) PAHs Testing (Food and Textile)
04 .24.2025
JJR Lab offers testing for PAHs in textiles, tires, and rubber products, ensuring compliance with EU...
Where to Apply for the EU RoHS Test Report? Where to Apply for the EU RoHS Test Report?
04 .24.2025
Need EU RoHS testing? JJR Lab in China offers fast, certified compliance for electronics and compone...
Children’s Products and Toy Testing Children’s Products and Toy Testing
04 .24.2025
Children’s toys impact safety and growth. China JJR Lab tests to EN 71, ASTM F963, ISO 8124, GB 6675...
What is a GB 31701 Test Report? What is a GB 31701 Test Report?
04 .24.2025
GB 31701 sets safety standards for children’s textiles in China. JJR Lab offers professional testing...
UN 38.3 Transportation Test UN 38.3 Transportation Test
04 .23.2025
UN 38.3 transportation tests, required for battery exports, assess safety and performance through va...
Toxicological Risk Assessment of Medical Devices Toxicological Risk Assessment of Medical Devices
04 .23.2025
JJR Lab offers toxicological risk assessment for medical devices, following ISO 10993 and ISO 18562 ...
How to get the Vacuum Cleaner UL 1017 Test Report? How to get the Vacuum Cleaner UL 1017 Test Report?
04 .23.2025
Submit samples to China JJR Lab for UL 1017 testing, ensuring full compliance with North American sa...