We understand that you are looking for an EMC (Electro Magnetic Compatibility) testing laboratory in Ukraine. However, we still want to help you understand us; because compared to local Australian laboratories, we can save you 30% on testing and certification costs.
JJRLAB is a Chinese EMC electromagnetic compatibility testing laboratory; we are an ISO/IEC 17025 and GLP laboratory. Welcome to learn more about us.
JJRLAB has established a comprehensive independent testing system, consisting of four standard 3-meter anechoic chambers, one RF full-wave anechoic chamber, one set of RS test systems, three interference testing rooms, and four shielded rooms. The testing instruments are advanced and manufactured and constructed by well-known international companies in the industry such as Germany's Rohde & Schwarz, TESEQ, Schwarzbeck, Switzerland's EMTEST, HAEFELY, EMC Partner, America's Agilent, FCC, and others. The technical team is composed of a group of professionals and expert consultants with many years of experience in EMC testing, countermeasures, and certification work, capable of providing one-stop services for electronic enterprises from PCB layout design, circuit parameter calculation, component specification selection to complete system integration, product testing, countermeasures, and certification.
◆ Automotive Electronic EMC
◆ Aerospace Electronic EMC
◆ Rail Transportation Electronic EMC
◆ Consumer Electronics EMC
➢ Radiated Emissions (RE) Testing
➢ Conducted Emissions (CE) Testing
➢ Disturbance Power Testing
➢ Harmonic Current Testing
➢ Voltage Fluctuation Testing
➢ Electrostatic Discharge (ESD) Testing
➢ Radiofrequency Electromagnetic Field Immunity (RI) Testing
➢ Electrical Fast Transient Burst Immunity (EFT) Testing
➢ Surge (Lightning & Surges) Immunity Testing
➢ Radiofrequency Field Induced Conducted Immunity (CI) Testing
➢ Power Frequency Magnetic Field Immunity (PFMI) Testing
➢ Voltage Dips, Short Interruptions, Voltage Variation Immunity (DIPS) Testing
Europe: CE-EMC, E-Mark
North and South America: FCC, ISED, IC
Asia: VCCI, BSMI, CCC, CQC, MSIP, PSE, SIRIM, TISI, ISI
Australia and Africa: RCM, SABS
GB/T 17619 "Electromagnetic Radiation Susceptibility Limits and Measurement Methods for Automotive Electronic Components"
ISO 7637-1/-2/-3, GB/T 21437.1/.2/.3 "Electrical Disturbances Caused by Conduction and Coupling in Road Vehicles"
ISO 10605 "Test Methods for Electrical Disturbances from Electrostatic Discharge in Road Vehicles"
GB/T 19951 "Test Methods for Electrical Disturbances from Electrostatic Discharge in Road Vehicles"
GB/T 28046.2 "Environmental Conditions and Tests for Electrical and Electronic Equipment for Road Vehicles - Part 2: Electrical Loads"
ISO 16750-2 "Environmental Conditions and Tests for Electrical and Electronic Equipment for Road Vehicles - Part 2: Electrical Loads"
ISO 21848 "Electrical Loads of 42V Power Supply Voltage for Road Vehicles"
ISO 11452-1/-2/-3/-4/-5/-7/-8/-9/-10/-11 "Electromagnetic Disturbance Resistance Test Methods for Electrical/Electronic Components of Road Vehicles to Narrowband Radiated Electromagnetic Energy"
GB/T 18655 "Limits and Measurement Methods for Radio Disturbance Characteristics for Vehicles, Boats, and Internal Combustion Engines to Protect On-Board Receivers"
CISPR 25 "Limits and Measurement Methods for Radio Disturbance Characteristics of Vehicles, Boats, and Internal Combustion Engines to Protect On-Board Receivers"
IEC 61547/GB T 18595 "Electromagnetic Compatibility Immunity Requirements for General Lighting Equipment"
CISPR 15/GB 17743 "Limits and Measurement Methods for Radio Disturbance Characteristics of Electrical Lighting and Similar Equipment"
IEC 61000-3-2 "Electromagnetic Compatibility - Limits - Harmonic Current Emission Limits (Equipment with Input Current ≤16A per Phase)"
GB 17625.1 "Electromagnetic Compatibility - Limits - Harmonic Current Emission Limits (Equipment with Input Current ≤16A per Phase)"
IEC 61000-3-3 "Electromagnetic Compatibility - Limits - Limitations for Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems for Equipment with Rated Current ≤16A and Subjected to Conditional Connection"
GB 17625.2 "Electromagnetic Compatibility - Limits - Limitations for Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems for Equipment with Rated Current ≤16A and Subjected to Conditional Connection"
IEC 62493/GB T31275: "Assessment of Human Exposure to Electromagnetic Fields from Lighting Equipment"
IEC 60947-1/GB 10408.1: "Low-Voltage Switchgear and Controlgear - Part 1: General Rules"
IEC 60947-2/GB 10408.2: "Low-Voltage Switchgear and Controlgear - Part 2: Circuit Breakers"
IEC 60947-3/GB 10408.3: "Low-Voltage Switchgear and Controlgear - Part 3: Switches, Disconnectors, Switch-Disconnectors, and Fuse-Combination Units"
IEC 60947-4/GB 10408.4: "Low-Voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor Starters - Electromechanical Contactors and Motor Starters (Including Motor Protectors)"
IEC 60947-5/GB 10408.5: "Low-Voltage Switchgear and Controlgear - Part 5-1: Control Circuit Devices and Switching Elements - Electromechanical Control Circuit Devices"
IEC 60947-6/GB 10408.6: "Low-Voltage Switchgear and Controlgear - Part 4-2: Contactors and Motor Starters - AC Semiconductor Motor Controllers and Starters (Including Soft Starters)"
IEC 60947-10/GB 10408.10: "Low-Voltage Switchgear and Controlgear - Part 5-2: Control Circuit Devices and Switching Elements - Proximity Switches"
CISPR 11/EN 55011/GB 4824: "Limits and Measurement Methods of Industrial, Scientific, and Medical (ISM) Radio-Frequency Equipment Electromagnetic Disturbance Characteristics"
IEC 60601-1-2/YY 0505: "Medical Electrical Equipment - Part 1-2: General Requirements for Safety - Collateral Standard: Electromagnetic Compatibility - Requirements and Tests"
IEC 61326-1/GB T18268.1: "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 1: General Requirements"
IEC 61326-2-6/GB T18268.26: "Electrical Equipment for Measurement, Control, and Laboratory Use - EMC Requirements - Part 26: In Vitro Diagnostic (IVD) Equipment"
IEC 61000-3-2/GB 17625.1: "Electromagnetic Compatibility - Limits - Harmonic Current Emission Limits (Equipment with Input Current ≤16
A per Phase)"
IEC 61000-3-3/GB 17625.2: "Electromagnetic Compatibility - Limits - Limitations for Voltage Changes, Voltage Fluctuations, and Flicker in Public Low-Voltage Supply Systems for Equipment with Rated Current ≤16A and Subjected to Conditional Connection"
IEC 61000-3-2/GB 17625.1: "Electromagnetic Compatibility - Limits - Harmonic Current Emission Limits (Equipment with Input Current ≤16A per Phase)"
CISPR 14-1/GB 4343.1: "Electromagnetic Compatibility Requirements for Household Electrical Appliances, Electric Tools, and Similar Apparatus - Part 1: Emission"
CISPR 14-2/GB 4343.2: "Electromagnetic Compatibility Requirements for Household Electrical Appliances, Electric Tools, and Similar Apparatus - Part 2: Immunity"
CISPR 22/EN 55022/GB 9254: "Radio Disturbance Characteristics of Information Technology Equipment - Limits and Methods of Measurement"
CISPR 24/GB/T 17618: "Electromagnetic Compatibility - Immunity Requirements and Measurement Methods for Information Technology Equipment"
24-hour online customer service at any time to respond, so that you worry!