Selling baby pacifiers and pacifier clips on the Amazon platform requires strict adherence to regulations and standards to ensure the safety of babies. Below are the detailed requirements:

 

Standards for Baby Pacifiers

Products must meet one of the following standards:

1. AS 2432:2015 Standard

If your product is intended for the Australian market, it must comply with AS 2432:2015 (Infant pacifiers).

- This standard specifies requirements for materials, structural design, and other aspects to ensure the safety and comfort of babies.

 

2. EN 1400:2013+A1:2014 Standard

According to the 2017 Consumer Goods (Baby Dummies and Dummy Chains) Safety Standard, products for the European market must comply with EN 1400:2013+A1:2014 (Child use and care articles - Soothers for babies and young children - Safety requirements and test methods).

- This standard focuses on safety requirements and testing methods to ensure the pacifiers do not pose any harm to babies during use.

 

Regulations for Pacifier Clips

Products must comply with all the following regulations:

1. EN 12586:2008+A1:2011 Standard

According to the 2017 Consumer Goods (Baby Dummies and Dummy Chains) Safety Standard, products for the European market must comply with EN 12586:2008+A1:2011 (Child use and care articles - Soother holders - Safety requirements and test methods).

- This standard covers the strength, dimensions, and harmful substance content of pacifier clips to prevent risks such as strangulation or ingestion of small parts during use.

 

2. Consumer Protection Notice No. 11 of 2011

If the product falls under the requirements of this notice, compliance is also mandatory.

- This notice further standardizes safety indicators for pacifier clips from the perspective of consumer rights protection.

 

Required Documentation

To demonstrate product compliance, sellers must provide the following:

1. Test Reports

- Test reports must be issued by laboratories accredited by ISO 17025, the National Association of Testing Authorities in Australia, or the China National Accreditation Service for Conformity Assessment (e.g., China JJR Laboratory).

- The report should clearly demonstrate that the product meets the above-mentioned regulations and standards.

 

2. Images

- Clear images of the product manual and instructions must be provided.

- The images should verify that the product matches both the tested item and the product displayed on the product detail page. The following details must be included:

- Product manual, instructions, safety information, labels, and warnings.

- All information must be in the language of the target sales country/region.

- For bundled or packaged products, provide images for each item included.

- Where possible, submit images showing all sides of the product or its packaging to expedite approval and reduce the likelihood of delays in the approval process.

 

Following these requirements and ensuring product compliance are critical steps for sellers to successfully list and safely sell their products on Amazon.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Packaging Validation ISO 11607 Test Report Packaging Validation ISO 11607 Test Report
04 .25.2025
ISO 11607 packaging validation testing provided by China’s JJR Lab ensures medical devices meet safe...
What is the ISO 11607-1 Packaging Validation Test? What is the ISO 11607-1 Packaging Validation Test?
04 .25.2025
ISO 11607-1 ensures sterile medical packaging meets global safety standards. JJR Lab in China offers...
How to get an ISO 11737-1 Test Report? How to get an ISO 11737-1 Test Report?
04 .25.2025
Bioburden testing per EN ISO 11737-1 ensures medical device safety pre-sterilization. JJR Lab in Chi...
Orthopedic Implant Cleanliness Testing Orthopedic Implant Cleanliness Testing
04 .25.2025
Orthopedic implant cleanliness is key for biocompatibility and sterilization. China JJR Laboratory o...
What is ISO 10993-23:2021 Irritation Testing? What is ISO 10993-23:2021 Irritation Testing?
04 .25.2025
ISO 10993-23:2021 evaluates irritation risks of medical devices using in vitro/in vivo methods. JJR ...
ISO 10993-23 Irritation Testing Laboratory ISO 10993-23 Irritation Testing Laboratory
04 .25.2025
ISO 10993-23 irritation testing ensures device safety for skin, eyes, and mucosa. Professional testi...
EMI Emissions Testing EMI Emissions Testing
04 .25.2025
EMI emissions testing of electric/magnetic fields & disturbance power per CISPR standards. JJR L...
EMC Standards for Medical Devices EMC Standards for Medical Devices
04 .25.2025
EMC standards like IEC 60601-1-2 are vital for medical devices. China’s JJR Lab provides testing for...

Leave Your Message