In response to market and consumer concerns about mask quality and safety, as well as the demand for mask exports overseas, China JJR Laboratory has invested over one million USD in advanced mask testing equipment and actively sought recognition from national and international organizations to provide fast, flexible, and professional internationally recognized mask testing services. Today, JJR has obtained dual recognition from the China National Accreditation Service for Conformity Assessment (CNAS) and the International Accreditation Service (IAS), offering mask testing services accredited by the International Laboratory Accreditation Cooperation (ILAC).
China JJR Laboratory provides comprehensive international standard testing such as: Australia AS4381: 2015, China YY0469-2011, YY/T0969-2013, and GB15979, European Union EN 14683: 2019+AC: 2019, and the United States ASTM F2100-19, meeting the requirements for mask exports to different countries and registration.
- Bacterial Filtration Efficiency (BFE) %:
- Level 1: ≥95
- Level 2: ≥98
- Level 3: ≥98
- Testing Method: ASTM F2101
- Particulate Filtration Efficiency (PFE) % @0.1 micron:
- Level 1: ≥95
- Level 2: ≥98
- Level 3: ≥98
- Testing Method: ASTM F2299
- Pressure Differential (mmH₂O/cm²):
- Level 1: <5.0
- Level 2: <6.0
- Level 3: <6.0
- Testing Method: EN 14683
- Synthetic Blood Penetration Resistance (mmHg):
- Level 1: 80
- Level 2: 120
- Level 3: 160
- Testing Method: ASTM F1862
- Flammability Test:
- Level 1: Class 1
- Level 2: Class 1
- Level 3: Class 1
- Testing Method: 16 CFR 1610
- Bacterial Filtration Efficiency (BFE) %:
- Level I: ≥95
- Level II: ≥98
- Level IIR: ≥98
- Testing Method: EN 14683
- Pressure Differential (Delta P) (Pa/cm²):
- Level I: <40
- Level II: <40
- Level IIR: <60
- Testing Method: EN 14683
- Splash Resistance (kPa):
- Level I: Not Required
- Level II: Not Required
- Level IIR: ≥16.0 (120 mmHg)
- Testing Method: EN 14683
- Microbial Cleanliness (CFU/g):
- Level I: ≤30
- Level II: ≤30
- Level IIR: ≤30
- Testing Method: EN 14683
- Bacterial Filtration Efficiency (BFE) %:
- Level 1: ≥95
- Level 2: ≥98
- Level 3: ≥98
- Testing Method: EN 14683
- Pressure Differential (mmH₂O/cm²):
- Level 1: <4.0
- Level 2: <5.0
- Level 3: <5.0
- Testing Method: EN 14683
- Synthetic Blood Penetration Resistance (mmHg):
- Level 1: 80
- Level 2: 120
- Level 3: 160
- Testing Method: ISO 22609
- Cell Toxicity: ISO 10993-5
- Irritation: iso 10993-10
- Skin Sensitization: ISO 10993-10
In addition to the above standards, our center also offers various mask tests to meet different market requirements, including:
- Viral Filtration Efficiency (VFE) %
- GB 15979 Microbial Indicator Requirements
- Antibacterial Efficiency Testing
- Antiviral Efficiency Testing
To meet the large demand for mask testing and to ensure timely reporting, China JJR Laboratory has invested over one million USD in advanced mask testing equipment to immediately improve the mask testing capacity and speed.
24-hour online customer service at any time to respond, so that you worry!