Biocompatibility Testing Services

Views :
Update time : 2025-11-10

biocompatibility testing Projects

There are numerous biocompatibility testing projects. Medical device manufacturers shoULd select testing projects based on their product's usage characteristics, product standards, the body parts involved, and the duration of contact, in accordance with the relevant standards for their specific products.

JJR Laboratory in China offers customized testing plans for clients based on the characteristics and intended use of the medical device, providing a full range of ISO 10993 and ISO 18562 Biocompatibility Testing Services.

 

Testing Standards:

Biocompatibility Testing Projects:

- In vitro cytotoxicity test

- Salmonella typhimurium reverse mutation test

- Sensitization test

- Gene mutation test

- Thrombosis test

- Skin irritation test

- Intracutaneous irritation test

- Coagulation test

- Acute systeMIC toxicity test

- Subacute systemic toxicity test

- Platelet adhesion test

- Complement activation test

- Subchronic systemic toxicity test

- Chronic systemic toxicity test

- Muscle implantation test

- Hemolysis test

- Pyrogenicity test

- Chromosomal aberration test

- Bone implantation test

- Bone marrow micronucleus test

- Material characterization analysis

- Subcutaneous implantation test

 

Non-poweRED | Biocompatibility Testing Standards:

1. in vitro cytotoxicity test: ISO10993-5, GB16886.5

2. Sensitization test: ISO10993-10, GB16886.10

3. Skin, intracutaneous, oral mucosa irritation test: ISO10993-10, GB16886.10

4. Irritation test: ISO10993-23

5. Acute systemic toxicity test: ISO10993-11, GB16886.11

6. Subacute systemic toxicity test: ISO10993-11, GB16886.11

7. Subchronic systemic toxicity test: ISO10993-11, GB16886.11

8. Chronic systemic toxicity test: ISO10993-11, GB16886.11

9. Pyrogenicity test: ISO10993-11, GB16886.11

10. Chromosomal aberration test: ISO10993-3, GB16886.3

11. Micronucleus test: ISO10993-3, GB16886.3

12. Gene mutation test: ISO10993-3, GB16886.3

13. Ames test: ISO10993-3, GB16886.3

14. Thrombosis test: ISO10993-4, GB16886.4

15. Coagulation test: ISO10993-4, GB16886.4

16. Platelet adhesion test: ISO10993-4, GB16886.4

17. Complement activation test: ISO10993-4, GB16886.4

18. Hemolysis test: ISO10993-4, GB16886.4

19. Muscle implantation test: ISO10993-6, GB16886.6

20. Subcutaneous implantation test: ISO10993-6, GB16886.6

21. Bone implantation test: ISO10993-6, GB16886.6

22. Material characterization analysis: ISO10993-18

 

Our Advantages:

- The laboratory holds CNAS/national CMA and OECD GLP qualifications.

- Covers in vivo and in vitro testing.

- Full range of tests in compliance with various standards (such as product standards, ISO 10993, ASTM, MHLW, GBT 16886, USP, EP, BP, etc.).

- Customized testing plans: We can combine local tissue reaction implantation tests with systemic toxicity tests, or integrate biocompatibility testing with preclinical large animal studies, helping to save on testing costs and time.

- Biological risk assessment: By combining all available safety-related data, senior toxicology experts evaluate the biological risks and optimize the testing plan, saving both time and costs!


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
What is the EN 61326-2-3 Standard? What is the EN 61326-2-3 Standard?
01 .31.2026
EN 61326-2-3 ensures EMC compliance for sensors, transmitters, lab & industrial equipment. JJR o...
Why Do Smart Sockets Need IEC 60884 Certification? Why Do Smart Sockets Need IEC 60884 Certification?
01 .31.2026
Smart sockets need IEC 60884 certification for safety & market ; JJR CNAS/ILAC/ISO17025 labs pro...
Why Retest the Device if the 5G Module Already Has Why Retest the Device if the 5G Module Already Has
01 .31.2026
Even if a 5G module is CE-certified, the whole device needs testing per EU RED; JJR LAB provides ISO...
Overview of IEC 62087 Test Standard Overview of IEC 62087 Test Standard
01 .31.2026
IEC 62087 defines power-consumption tests for TVs, monitors, audio/video devices. JJR Lab (CMS, CNAS...
CISPR 25 Test Standard Compliance Guide CISPR 25 Test Standard Compliance Guide
01 .31.2026
Automakers face EMI in smart vehicles; CISPR 25 & GB/T 18655 ensure CE/RE compliance. JJR Lab (C...
IEC/UL/CSA 62368-1 Electrical Distance Testing IEC/UL/CSA 62368-1 Electrical Distance Testing
01 .31.2026
IEC/UL/CSA 62368-1 electrical distance testing supports global market access. CMS, CNAS, ISO/IEC 170...
Canada Wireless Device IC Certification RSS-210 Te Canada Wireless Device IC Certification RSS-210 Te
01 .30.2026
Canada Wireless Device IC Certification RSS-210 testing by JJR, a CMS, CNAS, ISO/IEC 17025 lab, cove...
FCC Part 15.231 for Wireless Remote Controls and S FCC Part 15.231 for Wireless Remote Controls and S
01 .30.2026
FCC Part 15.231 testing for wireless remotes and sensors, covering RF, EMC, bandwidth and duty cycle...

Leave Your Message