EMC China Lab

Biocompatibility Testing Services

Views :
Update time : 2025-11-10

biocompatibility testing Projects

There are numerous biocompatibility testing projects. Medical device manufacturers should select testing projects based on their product's usage characteristics, product standards, the body parts involved, and the duration of contact, in accordance with the relevant standards for their specific products.

JJR Laboratory in China offers customized testing plans for clients based on the characteristics and intended use of the medical device, providing a full range of ISO 10993 and iso 18562 Biocompatibility Testing Services.

 

Testing Standards:

Biocompatibility Testing Projects:

- In vitro cytotoxicity test

- Salmonella typhimurium reverse mutation test

- Sensitization test

- Gene mutation test

- Thrombosis test

- Skin irritation test

- Intracutaneous irritation test

- Coagulation test

- Acute systemic toxicity test

- Subacute systemic toxicity test

- Platelet adhesion test

- Complement activation test

- Subchronic systemic toxicity test

- Chronic systemic toxicity test

- Muscle implantation test

- Hemolysis test

- Pyrogenicity test

- Chromosomal aberration test

- Bone implantation test

- Bone marrow micronucleus test

- Material characterization analysis

- Subcutaneous implantation test

 

Non-powered | Biocompatibility Testing Standards:

1. in vitro cytotoxicity test: ISO10993-5, GB16886.5

2. Sensitization test: ISO10993-10, GB16886.10

3. Skin, intracutaneous, oral mucosa irritation test: ISO10993-10, GB16886.10

4. Irritation test: ISO10993-23

5. Acute systemic toxicity test: ISO10993-11, GB16886.11

6. Subacute systemic toxicity test: ISO10993-11, GB16886.11

7. Subchronic systemic toxicity test: ISO10993-11, GB16886.11

8. Chronic systemic toxicity test: ISO10993-11, GB16886.11

9. Pyrogenicity test: ISO10993-11, GB16886.11

10. Chromosomal aberration test: ISO10993-3, GB16886.3

11. Micronucleus test: ISO10993-3, GB16886.3

12. Gene mutation test: ISO10993-3, GB16886.3

13. Ames test: ISO10993-3, GB16886.3

14. Thrombosis test: ISO10993-4, GB16886.4

15. Coagulation test: ISO10993-4, GB16886.4

16. Platelet adhesion test: ISO10993-4, GB16886.4

17. Complement activation test: ISO10993-4, GB16886.4

18. Hemolysis test: ISO10993-4, GB16886.4

19. Muscle implantation test: ISO10993-6, GB16886.6

20. Subcutaneous implantation test: ISO10993-6, GB16886.6

21. Bone implantation test: ISO10993-6, GB16886.6

22. Material characterization analysis: ISO10993-18

 

Our Advantages:

- The laboratory holds CNAS/national CMA and OECD GLP qualifications.

- Covers in vivo and in vitro testing.

- Full range of tests in compliance with various standards (such as product standards, iso 10993, ASTM, MHLW, GBT 16886, USP, EP, BP, etc.).

- Customized testing plans: We can combine local tissue reaction implantation tests with systemic toxicity tests, or integrate biocompatibility testing with preclinical large animal studies, helping to save on testing costs and time.

- Biological risk assessment: By combining all available safety-related data, senior toxicology experts evaluate the biological risks and optimize the testing plan, saving both time and costs!


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
Introduction to RE, CE and ESD in EMC Testing Introduction to RE, CE and ESD in EMC Testing
04 .03.2026
JJR Lab : RE, CE and ESD ensure EMC compliance by controlling emissions and verifying immunity, so d...
EMC Testing: EMI / EMS / RE / CE / CS / ESD EMC Testing: EMI / EMS / RE / CE / CS / ESD
04 .03.2026
EMC ensures devices neither cause nor suffer interference. EMI (CE, RE) measures emissions, while EM...
Important: Latest Notice on SASO IEC 62680 Important: Latest Notice on SASO IEC 62680
04 .03.2026
SASO delays IEC 62680 enforcement to May 1, 2026; non-compliant devices lose COC eligibility. JJR LA...
What is BS EN 1388-2 Certification Testing What is BS EN 1388-2 Certification Testing
04 .03.2026
EN 1388-2 strictly limits lead/cadmium in ceramic tableware; JJR LAB tests heavy metal migration usi...
How to get a BS EN 1388-1 Compliance Report? How to get a BS EN 1388-1 Compliance Report?
04 .03.2026
Ceramic tableware must meet BS EN 1388-1 limits for lead/cadmium; tested via EN 1388-2 under simulat...
What is BS EN 1388-1 Certification Testing? What is BS EN 1388-1 Certification Testing?
04 .03.2026
BS EN 1388-1 tests ceramic foodware for lead and cadmium migration, ensuring full CE compliance and ...
What is FCC ID Used For What is FCC ID Used For
04 .02.2026
FCC ID ensures wireless devices meet US RF, SAR, and EMC safety standards; JJR Lab provides professi...
AS/NZS 4417.2:2020 Amd 1:2026 Australia and New Ze AS/NZS 4417.2:2020 Amd 1:2026 Australia and New Ze
04 .02.2026
AS/NZS 4417.2:2020 Amd 1:2026 strengthens AU/NZ electrical safety by adding categories, tightening c...

Leave Your Message