EMC China Lab

Amazon Climbing Carabiner ASTM F1774 Certification Testing

Views :
Update time : 2025-01-02

A climbing carabiner is a metal ring with a spring mechanism used for quickly and reversibly connecting components during rock climbing and mountaineering, forming a critical part of safety systems. Climbing carabiners are used to attach ropes to equipment or to connect multiple pieces of gear together. They are typically made of aluminum or steel. On Amazon’s U.S. site, climbing carabiners generally need to meet the ASTM F1774 standard established by the American Society for Testing and Materials (ASTM). The ASTM F1774 standard outlines the performance and safety requirements for connectors in climbing and mountaineering equipment, covering aspects such as strength, durability, corrosion resistance, and ease of use.

 

Amazon Climbing Carabiner ASTM F1774 Certification Testing(图1)


Main ASTM F1774 Standard Test Items:

1. Strength Test: Ensures that the carabiner does not break or fail under specified loads.

2. Durability Test: Simulates long-term use and wear to check the carabiner's durability.

3. Corrosion Resistance Test: Assesses the carabiner's resistance to corrosion under various environmental conditions.

4. Usability Evaluation: Ensures the carabiner is easy to operate and prevents safety risks caused by misuse.

 

Requirements for Listing Climbing Carabiners on Amazon U.S. Site:

1. Compliance with Safety Standards: Sellers must ensure their climbing and mountaineering products meet the ASTM F1774 safety standard.

2. Laboratory Testing: The product must pass testing from an ISO/IEC 17025 certified laboratory that is a member of ILAC MRA (International Laboratory Accreditation Cooperation Mutual Recognition Arrangement). Sellers must provide relevant test reports to prove product safety and compliance.

3. Provide Test Reports: The test report must be provided by a qualified third-party laboratory and should reflect the product’s compliance with the respective standards.

4. Product Labeling: All climbing and mountaineering gear should clearly display the safety standards it complies with, manufacturer information, production date, and product batch numbers.

5. Safety Instructions and Warning Labels: The product page must provide clear usage instructions, risk warnings, and necessary safety information to consumers.

 

Notes:

1. Product Packaging: Labels and packaging must meet Amazon’s requirements and match the images provided in the test report.

2. Test Reports Must Include Product Images: The test report must contain images of the product, including packaging and warning labels. These images should match the ones on the product detail page. All submitted materials must be authentic, credible, and accurate.


Email:hello@jjrlab.com


Leave Your Message


Write your message here and send it to us


Related News
Read More >>
China OECD GLP-Certified Laboratory China OECD GLP-Certified Laboratory
04 .26.2025
China JJR Lab, OECD GLP certified, offers trusted biocompatibility testing with global recognition a...
Packaging Validation ISO 11607 Test Report Packaging Validation ISO 11607 Test Report
04 .25.2025
ISO 11607 packaging validation testing provided by China’s JJR Lab ensures medical devices meet safe...
What is the ISO 11607-1 Packaging Validation Test? What is the ISO 11607-1 Packaging Validation Test?
04 .25.2025
ISO 11607-1 ensures sterile medical packaging meets global safety standards. JJR Lab in China offers...
How to get an ISO 11737-1 Test Report? How to get an ISO 11737-1 Test Report?
04 .25.2025
Bioburden testing per EN ISO 11737-1 ensures medical device safety pre-sterilization. JJR Lab in Chi...
Orthopedic Implant Cleanliness Testing Orthopedic Implant Cleanliness Testing
04 .25.2025
Orthopedic implant cleanliness is key for biocompatibility and sterilization. China JJR Laboratory o...
What is ISO 10993-23:2021 Irritation Testing? What is ISO 10993-23:2021 Irritation Testing?
04 .25.2025
ISO 10993-23:2021 evaluates irritation risks of medical devices using in vitro/in vivo methods. JJR ...
ISO 10993-23 Irritation Testing Laboratory ISO 10993-23 Irritation Testing Laboratory
04 .25.2025
ISO 10993-23 irritation testing ensures device safety for skin, eyes, and mucosa. Professional testi...
EMI Emissions Testing EMI Emissions Testing
04 .25.2025
EMI emissions testing of electric/magnetic fields & disturbance power per CISPR standards. JJR L...

Leave Your Message