Radio frequency electromagnetic field radiated immunity, also known as radiated sensitivity or immunity, R/S, is one of the most basic electromagnetic compatibility immunity testing items. It refers to the ability of various devices, equipment, or systems to resist radiation in the presence of a radiated electromagnetic field. The higher the sensitivity, the lower the immunity. For example, electromagnetic fields generated by radio stations, television stations, fixed or mobile radio transmitters, and various industrial radiation sources typically have a measurement frequency range of 80 MHz to 6 GHz.
For products such as electric bicycles, electric scooters, and industrial trucks, the lower frequency limit of the measurement range is reduced from the conventional standard of 80 MHz to 20 MHz, and the field strength increases to a maximum of 30 V/m. Electric bicycles, electric scooters, and industrial trucks operating in this electromagnetic field will be affected by it, potentially impacting the normal operation of the equipment.
China's JJR organization has a professional testing laboratory with complete qualifications, capable of providing one-stop radiated immunity testing and certification services.
For electronic products requiring low-frequency radiated immunity testing as specified by the standards, JJR can provide pre-testing, issue test reports, and certification services.
- European Standards
- EN 17128
- EN 15194
- EN 12895
- UK Standards
- BS EN 17128
- BS EN 15194
- BS EN 12895
20 MHz – 100 MHz, at 3 meters: 30V/m
- Power Port: AC 690V, 300A, Single-phase/Three-phase
- DC Port: DC 1800V, 30A MAX (DC source provided by the customer can be increased to 200A)
1 set of samples (If the test fails, we can provide rectification services separately)
Maximum Size of Test Products
1.5m (Width) × 2m (Height)
- Single Test: Test results will be provided within 3 working days. If a report is required, an additional 2 working days will be needed.
- Certification: Product certification includes multiple items, with low-frequency radiated immunity being one of them. The overall cycle is generally 15 working days.
The validity period is determined by the standard. If there are no significant technical changes, the standard can be updated directly. Please consult technical support for specific details.
China JJR Laboratory
International Electrotechnical Commission (IEC) and national standard committees
China JJR Laboratory
Product technical specifications; for complex products, the product manual and auxiliary equipment should be provided.
24-hour online customer service at any time to respond, so that you worry!